To
further illustrate how using TMT bars can lead
to huge savings in steel, please have a look at
the following international examples.
Steel savings on use of Hy-Tuf Thermex
500 bars instead of reinforcement steel 415:
| |
|
Office
in Berlin |
 |
 |
 |
 |
|
 |
 |
 |
 |
 |
 |
Building
of pre-cast members
11 storeys |
|
 |
 |
Component |
 |
 |
 |
Saving |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Column Distance
|
 |
 |
 |
7.20 m
|
 |
 |
 |
Columns
|
 |
 |
 |
15.2 %
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Floor Span
|
 |
 |
 |
7.20 m
|
 |
 |
 |
Beams
|
 |
 |
 |
13.4 %
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Storey Height
|
 |
 |
 |
3.30 m
|
 |
 |
 |
Floor Slabs
|
 |
 |
 |
08.3 %
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
 |
|
 |
 |
 |
Foundations
|
 |
 |
 |
14.3 %
|
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
TOTAL SAVINGS |
 |
 |
 |
|
 |
 |
 |
|
 |
 |
 |
12.8 %
|
 |
 |
 |
 |
 |
 |
 |
|
| Hotel
in Berlin |
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Combination
of monolithic & precast construction |
|
 |
 |
Component |
 |
 |
 |
Saving |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Column
Distance
|
 |
 |
 |
6.00m
|
 |
 |
 |
I
& II Floor, Beams & Columns
|
 |
 |
 |
16.2
%
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Floor
Span
|
 |
 |
 |
7.20
m
|
 |
 |
 |
Upper
Floors, Beams & Columns
|
 |
 |
 |
13.1
%
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Height
1st & 2nd Floor
|
 |
 |
 |
4.80
m
|
 |
 |
 |
External
Walls, Foundations
|
 |
 |
 |
13.8
%
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Height
Upper Storeys
|
 |
 |
 |
3.30
m
|
 |
 |
 |
|
 |
 |
 |
|
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
TOTAL
SAVINGS |
 |
 |
 |
|
 |
 |
 |
|
 |
 |
 |
14.1
%
|
 |
 |
 |
 |
 |
 |
 |
|
|
|
| House
in Berlin |
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Reinforced
concrete slab |
|
 |
 |
Component |
 |
 |
 |
Saving |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Base
Area
|
 |
 |
 |
6.00m
|
 |
 |
 |
Basement
walls
|
 |
 |
 |
12.1
%
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Storey
Height
|
 |
 |
 |
7.20
m
|
 |
 |
 |
Basement
floors
|
 |
 |
 |
15.2
%
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Precast
reinforced concrete:    |
 |
 |
 |
|
 |
 |
 |
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Load
Bearing walls
|
 |
 |
 |
19
cm thick
|
 |
 |
 |
Ground
& 1st floor walls |
 |
 |
 |
06.3
%
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Non-bearing
walls
|
 |
 |
 |
10
cm thick
|
 |
 |
 |
Ground
& 1st floor members
|
 |
 |
 |
14.8
%
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Floor
Members
|
 |
 |
 |
19
cm thick
|
 |
 |
 |
Foundation |
 |
 |
 |
02.3
%
|
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
TOTAL
SAVINGS |
 |
 |
 |
|
 |
 |
 |
|
 |
 |
 |
11.9
%
|
 |
 |
 |
 |
 |
 |
 |
|
|
|
| Motel
in Dresden |
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Combination
of monolithic and pre-cast construction |
|
 |
 |
Component |
 |
 |
 |
Saving |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Ground
floor area partly as car park and restaurants
|
 |
 |
 |
Monolithic
parts Floor, beams, columns |
 |
 |
 |
14.6
%
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Upper
storey area hotel rooms and functional
rooms
|
 |
 |
 |
Pre-cast
members Floors, beams, columns, External
walls |
 |
 |
 |
09.7
%
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
 |
Foundations |
 |
 |
 |
08.5
%
|
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
TOTAL
SAVINGS |
 |
 |
 |
|
 |
 |
 |
10.6
%
|
 |
 |
 |
 |
 |
 |
 |
|
|
|
| |
|
Bridge
Over the Motorway Dresden - Leipzig |
 |
 |
 |
 |
|
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
Component |
 |
 |
 |
Saving |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Span of both
main parts
|
 |
 |
 |
22.0 m
|
 |
 |
 |
Foundations
and piers
|
 |
 |
 |
05.8 %
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Clearance Weight
|
 |
 |
 |
05.0 m
|
 |
 |
 |
Abutments bridge
beams
|
 |
 |
 |
01.0 %
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
 |
|
 |
 |
 |
Carriage way
slab webs, cross girders
|
 |
 |
 |
02.5 %
|
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
TOTAL SAVINGS |
 |
 |
 |
|
 |
 |
 |
|
 |
 |
 |
03.2 %
|
 |
 |
 |
 |
 |
 |
 |
|
|
 |